top of page

›

Wiley H. Bates Middle School Roof Replacement

Roof replacement and roofing tie-in design for approximately 58,500 square feet of a middle school, coordinated with an HVAC systemic renovation.

Wiley H. Bates Middle School Roof Replacement

Overview

As roofing subconsultant to James Posey Associates, the MEP prime consultant, REI prepared roof replacement and roofing tie-in construction documents for Wiley H. Bates Middle School as part of a mechanical renovation. REI's field investigation included an infrared survey and investigative test cuts to determine existing construction. REI then designed the replacement of approximately 58,500 square feet of gravel-surfaced asphalt built-up roofing with a new 4-ply asphalt fiberglass built-up roof with a reflective mineral-surfaced cap sheet (hybrid system) over tapered insulation on the existing metal and concrete decks. The drawings located new mechanical equipment and detailed tie-ins where units were replaced on roof sections that were not being reroofed, along with expansion joint replacement, perimeter and through-wall flashing replacement, scuppers, roof drains, parapets and penetrations. REI prepared the technical specifications, assisted with bidding and provided construction administration, including submittal and payment reviews, site visits and clarifications, in close coordination with the MEP prime throughout design, bidding and construction.


Scope of Work

  • Investigated existing roofs with an infrared survey and investigative test cuts

  • Designed replacement of approximately 58,500 square feet of gravel-surfaced built-up roofing with a 4-ply asphalt fiberglass built-up roof and reflective mineral-surfaced cap sheet over tapered insulation

  • Detailed roofing tie-ins where mechanical units were replaced on roofs not being reroofed

  • Detailed expansion joint replacement, perimeter and through-wall flashing replacement, scuppers, roof drains, parapets and penetrations

  • Prepared technical specifications and assisted with bidding

  • Provided construction administration, including submittal and payment reviews, site visits and clarifications


Results

  • Coordinated the roof design with the HVAC renovation through design, bidding and construction, giving a watertight finish at mechanical unit tie-ins on roofs that were not replaced


Project Details

Client: Anne Arundel County Public Schools

Location: Annapolis, Maryland

Market: K-12 Education

Project Category: Roofing

REI Role: Subconsultant to James Posey Associates

Design (Phase 3 drawings): August 2022

Construction: First phase summer 2023; roof replacement completed 2024

Area / Quantity: Approximately 58,500 square feet of roof replacement

System(s): 4-ply asphalt fiberglass built-up roofing with reflective mineral-surfaced cap sheet (hybrid system); Tapered insulation over existing metal and concrete roof decks; Stainless steel expansion joint covers, coping end dams and through-wall flashing

Associated Work: HVAC systemic renovation (James Posey Associates, MEP prime)

Services: Roof Condition Assessment • Infrared Roof Survey • Roof Replacement Design • Bidding Assistance • Submittal Review • Construction Administration

bottom of page