top of page

›

Pentagon RSAC Interstitial Space and Miscellaneous Waterproofing Repairs

Design-build waterproofing replacement at three areas of the Pentagon, a building listed in the National Register of Historic Places: an interstitial space above occupied rooms, the Mall Terrace moat, and the A Ring 5th floor cornice, with the building fully occupied throughout.

Pentagon RSAC Interstitial Space and Miscellaneous Waterproofing Repairs

Overview

As designer of record for design-builder Edifice Group, REI surveyed and documented existing conditions, observed test cuts at the Mall Terrace moat, and prepared an existing conditions report, a basis of design, and construction drawings and specifications for three leaking areas of the Pentagon. In the RSAC interstitial space, REI designed a fully adhered, reinforced cold fluid-applied waterproofing system with a slip-resistant top coat over the existing membrane, new floor expansion joints, stainless steel hanging gutters under the ceiling expansion joints, slab patches, rebuilt fire-rated partitions, and flashings at every pipe, conduit and duct penetration. At the Mall Terrace moat above, the concrete topping was removed and replaced over a new hot-applied rubberized asphalt membrane with insulation, protection and drainage courses, new expansion joint assemblies on raised curbs, rebuilt stairs, and copper through-wall flashing and counterflashing, with limestone wall panels removed and reset to install the flashings. At the A Ring 5th floor cornice, REI specified concrete repairs and a new elastomeric coating tinted to match the building. The design followed Washington Headquarters Services codes and the Pentagon's exterior and historic concrete standards. REI then reviewed submittals and observed construction through punch list.


Scope of Work

  • Surveyed the interstitial space, cornice and moat, observed test cuts through the moat topping, and reported conditions that differed from the Government's existing drawings

  • Prepared the basis of design and the issued-for-construction drawings and specifications

  • Interstitial space: reinforced cold fluid-applied waterproofing with slip-resistant top coat, new floor expansion joints, stainless steel hanging gutters with EPDM curtains at ceiling joints, slab patches and new concrete curbs, rebuilt fire-rated partitions, and membrane, collar or pitch pan flashings at every penetration

  • Mall Terrace moat: new hot-applied rubberized asphalt waterproofing with insulation, protection and drainage courses under a new concrete topping, expansion joint assemblies on raised curbs, drain hardware, rebuilt stairs and handrail, and elastomeric coating on the retaining walls

  • Removal and resetting of limestone wall panels to install copper through-wall flashing at the moat walls, with copper counterflashing at the retaining walls

  • A Ring 5th floor cornice: concrete repairs stained to match, elastomeric coating tinted to match the building, and new lead-coated copper coping at an elevator bump-out parapet

  • Construction administration: submittal reviews, site observation reports, color and mortar selections, and punch list inspections


Results

  • The work was carried out while the Pentagon remained fully occupied and functioning

  • Field observation caught and corrected installation problems such as penetrations flashed with pitch pans where the design called for individual membrane flashings, and through-wall flashing joints that were not stripped in


Project Details

Client: Department of Defense, Washington Headquarters Services, Facilities Services Directorate

Location: Arlington, Virginia

Market: Government

Project Category: Waterproofing

REI Role: Subconsultant (designer of record) to Edifice Group, Inc., design-build contractor

Design Completed: July 2014 (issued for construction)

Construction: July 2014 - 2015

Areas: RSAC interstitial space; Mall Terrace moat, stairs and walls; A Ring 5th floor cornice

System(s): Reinforced cold fluid-applied waterproofing with slip-resistant top coat; hot-applied rubberized asphalt waterproofing; expansion joint assemblies; copper through-wall flashing and counterflashing; elastomeric coating

Delivery Method: Design-build

Historic Designation: National Register of Historic Places (Reference No. 89000932)

Services: Waterproofing Design • Masonry Restoration Design • Submittal Review • Construction Administration

bottom of page