top of page

›

Tysons Park Place II Roof Terrace Paver Ballast Design

Wind uplift and overturning analysis to set paver weights and hold-down requirements for a new rooftop terrace on a high-rise office building in Tysons, Virginia.

Tysons Park Place II Roof Terrace Paver Ballast Design

Overview

Tysons Park Place II is a high-rise office building on Jones Branch Drive in McLean, Virginia, where a new rooftop terrace with pedestal-mounted pavers and planters was planned on the existing ballasted roof. REI was retained by the project architect to determine how heavy the pavers needed to be, or how they must be held down, to resist wind uplift. REI surveyed the roof, calculated wind pressures under ASCE 7-16, and applied the paver uplift method of SPRI RP-4. REI established the width of the roof perimeter zone and confirmed that the planned terrace lay entirely within the field of the roof. REI then analyzed overturning of pavers raised up to about 10 inches on pedestals. The minimum weight was 26.2 psf for unstrapped pavers and 10.5 psf for strapped pavers. REI recommended 3-inch unstrapped precast pavers, which the structural engineer confirmed the reinforced roof could carry. REI also confirmed that the soil-filled planters needed no added hold-downs, and that the pedestals must be noncombustible to meet the local fire code.


Scope of Work

  • Surveyed the existing roof, parapets and the area of the planned terrace

  • Calculated wind pressures under ASCE 7-16 and paver uplift under SPRI RP-4

  • Determined the perimeter zone width and set the minimum setback of the terrace from the roof edge

  • Analyzed paver overturning on pedestals up to about 10 inches high and set minimum paver weights for unstrapped and strapped installations

  • Evaluated a kerf-cut hold-down alternative and the stability of soil-filled planters

  • Recommended the paver system and noncombustible pedestals and issued a sealed letter with calculations


Project Details

Client: Tysons Park Place II

Location: McLean, Virginia

Market: Commercial

Project Category: Roofing

REI Role: Wind Uplift and Ballast Design Engineer

Analysis and ballast design: 2023

Building: High-rise office building

System(s): Precast concrete pavers on pedestals and planters over a ballasted roof

Services: Roof Survey • Wind Uplift Analysis • Paver Ballast Design