Old Stone Warehouse Structural Assessment, Monitoring and Timber Retrofits

Timber framing analysis, wall movement monitoring and structural retrofits for a three-story early 19th-century stone warehouse in downtown Fredericksburg, to determine whether its floors could support a proposed museum.

Old Stone Warehouse Structural Assessment, Monitoring and Timber Retrofits

Overview

The Old Stone Warehouse at 813 Sophia Street is an early 19th-century stone and timber building whose walls were badly deformed by early 20th-century road work and later stabilized with retaining walls. The City of Fredericksburg asked REI to determine whether the floor framing could support the occupant loads of a proposed museum. REI measured and analyzed the timber framing at each level, established a new monitoring system to track movement of the stone walls, and then designed timber retrofit columns to increase the capacity of the framing. The retrofit columns were installed in 2018.


Scope of Work

  • Measured and analyzed the timber joists, beams and columns at the attic, second and first floors to establish allowable live loads for code-permitted occupancies

  • Developed conservative design values for historic timbers of uncertain species and grade, accounting for surface deterioration, checks and out-of-plumb columns

  • Established new monitoring reference points and a monitoring log, with baseline measurements of the stone walls' lengths and widths

  • Reviewed previous reports on the building and identified code, egress and accessibility issues to resolve with the code official before a change of use

  • Designed four structural timber retrofit columns and connections, plus floorboard repairs and limited wood restoration

  • Assisted with bidding, reviewed submittals, and observed the column mock-up and installation


Results

  • Showed the first floor could support most occupancies, while the second floor and attic needed retrofits before public use

  • Confirmed the stone walls had stabilized since the retaining walls were built, with baseline readings that matched earlier measurements

  • Strengthened the framing with infill retrofit columns rather than replacing historic timbers


Project Details

Client: City of Fredericksburg, Parks and Public Facilities

Location: Fredericksburg, Virginia

Market: Historic

Project Category: Structural Repair

REI Role: Prime Consultant

Assessment Completed: May 2015

Retrofit Construction: April 2018

Building: Three-story (plus attic) early 19th-century stone and timber warehouse at Sophia and William Streets

System(s): Historic timber floor framing; new timber retrofit columns with steel plate and concealed connectors

Services: Structural Condition Assessment • Structural Monitoring • Structural Repair Design • Bidding Assistance • Submittal Review • Construction Administration