NIST Building 205 Light-Gauge Framing Design and Shop Drawings

Field survey, design and shop drawings for light-gauge steel framing supporting new metal wall and roof panels at a building on the NIST campus in Gaithersburg, Maryland.

NIST Building 205 Light-Gauge Framing Design and Shop Drawings

Overview

REI was retained by the installer to design the light-gauge steel framing for new metal wall and roof panels at Building 205 on the National Institute of Standards and Technology campus in Gaithersburg, Maryland. REI surveyed and measured the existing steel framing, girts and purlins, and coordinated with the new penthouse structure. REI designed the framing to the 2012 Maryland Building Performance Standards, which adopt the 2012 International Building Code, for components and cladding wind and snow loads. The design covered girts and purlins, gable wall columns, door framing, and connections to the existing columns and roof beams. REI prepared shop drawings with a roof plan, framing elevations and connection details, and revised them during construction.


Scope of Work

  • Field-measured the existing steel framing, girts, purlins and columns

  • Calculated components and cladding wind pressures and roof snow loads under the 2012 Maryland Building Performance Standards

  • Designed light-gauge steel girts, purlins and gable wall columns for the new metal panels

  • Designed connections to the existing steel columns and roof beams, and door framing

  • Prepared shop drawings with a roof plan, framing elevations and connection details, and issued revisions


Project Details

Client: National Institute of Standards and Technology (NIST)

Location: Gaithersburg, Maryland

Market: Government

Project Category: Facade

REI Role: Delegated Design Engineer for the cladding installer

Design and shop drawings: 2013

Building: Steel-framed laboratory support building

System(s): Light-gauge steel girts, purlins and gable columns supporting metal wall and roof panels

Services: Field Survey • Wind and Snow Load Analysis • Light-Gauge Framing Design • Shop Drawings