top of page

›

Mount Vernon Community School Roof Replacement and Structural Repairs

Investigation and replacement design for approximately 59,000 square feet of roofing at Mount Vernon Community School, with drainage, flashing and facade repairs, plus structural repair design for hidden conditions uncovered during construction.

Mount Vernon Community School Roof Replacement and Structural Repairs

Overview

For Alexandria City Public Schools, REI investigated the roofs at Mount Vernon Community School, a building constructed in 1923 with additions in 1941, 1950 and 1967. In March 2018 REI surveyed the roofs, observed test cuts made at its direction to determine existing construction, and reported on conditions and the extent of required work, recommending that newer metal and PVC roofs in good condition be kept. REI then designed the replacement of the existing CSPE (Hypalon) single-ply membrane with fully adhered PVC roofing over new tapered and flat insulation on existing gypsum, wood, steel and concrete roof decks. The base design also covered drainage modifications, new overflow scuppers and drains, perimeter and through-wall flashings, replacement of windows, doors and skylights, and brick facade repairs. When demolition uncovered hidden structural deficiencies, REI analyzed them and designed repairs, including a deficient steel lintel, unsupported masonry above duct openings, deteriorated dunnage posts and screen wall framing at the cooling tower, and dislocated masonry. During construction REI also found the courtyard masonry screen wall leaning more than four inches out of plumb, alerted ACPS to the safety hazard, and designed its repair. Construction by Simpson Unlimited, Inc. was substantially complete by fall 2019.


Scope of Work

  • Performed a field investigation with test cuts and prepared a report of findings and recommendations

  • Designed replacement of approximately 59,000 SF of single-ply roofing with fully adhered PVC membrane over tapered and flat insulation on gypsum, wood, steel and concrete decks

  • Designed primary drainage modifications, new overflow scuppers and drains, and perimeter and through-wall flashings

  • Included replacement of four windows, two access doors and two skylights, and repairs to the brick facade

  • Assisted with bidding and performed contract administration during construction

  • Designed structural repairs for conditions uncovered during demolition: a deficient steel lintel, reinforcement at masonry openings for HVAC ducts, deteriorated cooling tower dunnage posts (with a step-by-step shoring and column replacement sequence), dislocated masonry above the cafeteria, and the deteriorated cooling tower screen wall

  • Measured and reported an overturning courtyard masonry screen wall (more than 4 inches out of plumb), recommended immediate closure of the adjacent sidewalk, and specified partial removal and repair


Results

  • Identified and resolved hidden structural deficiencies during construction, including an imminent safety hazard at the courtyard screen wall

  • Unit-price allowances built into the contract offset much of the cost of the unforeseen structural work


Project Details

Client: Alexandria City Public Schools

Location: Alexandria, Virginia

Market: K-12 Education

Project Category: Roofing

REI Role: Prime Consultant

Investigation & Report: March - April 2018

Design & Bidding: April - October 2018

Construction: Late 2018 - October 2019

Area / Quantity: Approximately 59,000 SF of roofing

Contractor: Simpson Unlimited, Inc.

System(s): Fully adhered 60-mil fiberglass-reinforced PVC roofing membrane over tapered and flat polyiso insulation, replacing CSPE (Hypalon) membrane on gypsum, wood, steel and concrete decks; prefinished aluminum coping and counterflashing; stainless steel through-wall flashings; overflow scuppers and drains

Structural Repairs: Steel lintel replacement at a window opening; Support for masonry above HVAC duct openings; Replacement of deteriorated cooling tower dunnage posts; Repair of dislocated masonry above the cafeteria; Restoration of the cooling tower masonry screen wall

Services: Roof Condition Assessment • Roof Replacement Design • Masonry Restoration Design • Structural Repair Design • Bidding Assistance • Construction Administration