Walter S. Mills-Parole Elementary School Roofing for Additions and Renovations
Existing roof assessment with an infrared survey, and roofing and sheet metal design for the additions and renovations at an Anne Arundel County elementary school: about 39,000 square feet of new built-up roofing, new asphalt shingle roofs, and repairs to about 51,000 square feet of existing built-up roofing.

Overview
As roofing subconsultant to TCA Architects, REI supported the additions and renovations at Walter S. Mills-Parole Elementary School in Annapolis, Maryland, for Anne Arundel County Public Schools. REI first assessed the school's existing flat roofs, installed in 2008, with a visual survey, test cuts and a nighttime infrared thermographic survey confirmed with a capacitance moisture meter. The built-up roofs were found in good condition, with an estimated 15 years of remaining service life if minor repairs and periodic maintenance were performed, so REI recommended keeping them. REI then prepared the roofing outline specifications, drawings, specifications and unit price schedule for the project: new gravel-surfaced built-up roofing over insulation on the additions, asphalt shingle roofs on the steep-slope areas, prefinished metal wall panels, stainless steel and prefinished aluminum flashings, and maintenance and repairs to the existing roofs. During construction REI reviewed the roofing contractor's submittals.
Scope of Work
Assessed the existing built-up roofs with a visual survey, test cuts, an infrared thermographic survey and moisture meter readings, and reported on their condition, drainage and remaining service life
Prepared outline specifications, design development and construction drawings (sheets R-1 to R-11) and roofing specifications, coordinated with the architect's plans and review comments
Designed approximately 39,000 square feet of new gravel-surfaced, 4-ply built-up roofing over polyisocyanurate insulation and cover board, with tapered crickets, on the additions
Designed asphalt shingle roofing for steep-slope roofs, prefinished metal wall panels, and stainless steel and prefinished aluminum copings, counterflashings, gravel stops and expansion joint covers
Specified maintenance and repairs to approximately 51,000 square feet of existing built-up roofing, with a unit price schedule for wet insulation, membrane patches, gravel surfacing and crickets
Reviewed the roofing contractor's submittals and manufacturer warranty requirements during construction
Results
The assessment found the 2008 built-up roofs in good condition, so they were kept and repaired as part of the renovation rather than replaced
Project Details
Client: TCA Architects, for Anne Arundel County Public Schools
Location: Annapolis, Maryland
Market: K-12 Education
Project Category: Roofing
REI Role: Subconsultant to TCA Architects
Roof Assessment: March - June 2012
Design Completed: December 2012 (bid and construction documents)
Construction: 2013 - 2014
Area / Quantity: Approximately 39,000 SF of new roofing; Approximately 51,000 SF of existing roofing repaired
System(s): Gravel-surfaced 4-ply asphalt built-up roofing over polyisocyanurate insulation (Firestone, 20-year warranty specified); Asphalt shingles on steep-slope roofs; Prefinished metal wall panels; Stainless steel and prefinished aluminum flashings
Contractor: Oak Contracting, LLC, with Cole Roofing Company as roofing installer
Services: Roof Condition Assessment • Infrared Roof Survey • Roof Replacement Design • Roof Maintenance and Repair • Submittal Review