Maryland Archaeological Conservation Laboratory Siding, Waterproofing and Roofing Replacement
Complete replacement of the siding, foundation waterproofing and standing seam metal roofing at the state's archaeological conservation laboratory, to stop leaks and control humidity around irreplaceable collections.

Overview
The Maryland Archaeological Conservation Laboratory at Jefferson Patterson Park and Museum, completed in 1996, houses the state's archaeological collections. It had roof and wall leaks, leaks through its foundation walls, and high humidity and mold in several rooms. REI's 2016–2017 investigation used test cuts and water testing to trace the problems to failed foundation waterproofing, deteriorated and poorly ventilated wood siding, and an envelope with no continuous vapor barrier. REI designed replacement of all three systems, tied together into one continuous barrier, and administered construction through substantial completion in August 2022.
Scope of Work
Investigated the roofing, siding and foundation waterproofing with test cuts and water tests, and reviewed the original construction documents
Designed new rubberized asphalt foundation waterproofing with rigid insulation, foundation drains and concrete crack repairs
Designed replacement of the wood siding with cement board siding over a liquid-applied vapor barrier and continuous insulation
Designed a new standing seam metal roofing system with a vapor barrier and added insulation, tied into the wall vapor barrier
Added gutters, downspouts tied into storm drainage, and snow guards at roof eaves that previously had none
Prepared wind load, gutter and downspout calculations, and revised the bid documents for rebidding in 2019
Provided construction administration, including observation reports, RFIs, change orders and the substantial completion inspection
Results
Tied the foundation waterproofing, wall vapor barrier and roof vapor barrier into one continuous system to stop leaks and help control humidity in collection spaces
Replaced wood siding that had been repainted repeatedly with longer-lasting cement board siding, in a smooth finish to match surrounding buildings
Where existing foundation waterproofing was still sound, revised the scope during construction to reuse it, reducing excavation
Project Details
Client: Maryland Department of General Services, for Jefferson Patterson Park and Museum
Location: St. Leonard, Maryland
Market: Government
Project Category: Roofing / Facade / Waterproofing
REI Role: Prime Consultant to Maryland DGS
Design: Investigation report: January 2017; Construction documents: December 2017; revised for rebid June 2019
Construction Completed: August 2022
Area / Quantity: Approximately 44,000 SF of roofing and 16,000 SF of siding (2017 report estimates)
System(s): Standing seam metal roofing with vapor barrier and insulation; cement board siding over liquid-applied vapor barrier and continuous insulation; rubberized asphalt foundation waterproofing; hanging gutters and snow guards
Building: Laboratory completed 1996; CMU walls, steel and wood plank roof decks
Services: Facade Condition Assessment • Roof Condition Assessment • Water Testing • Facade Restoration Design • Roof Replacement Design • Waterproofing Design • Construction Administration