top of page

›

Green Holly Elementary School Flat Roof Replacement and HVAC Renovation

Replacement of approximately 57,700 square feet of built-up flat roofing with a reflective hybrid built-up roof, together with new structural steel dunnage and roof framing reinforcement for new rooftop HVAC equipment.

Green Holly Elementary School Flat Roof Replacement and HVAC Renovation

Overview

As part of an HVAC renovation at Green Holly Elementary School, REI is the roofing and structural consultant to RTM Engineering Consultants (formerly Alban Engineering). REI surveyed the flat roofs visually and with infrared, and observed test cuts. The design replaces approximately 57,700 square feet of gravel-surfaced built-up roofing with a 4-ply asphalt fiberglass built-up roof and reflective mineral-surfaced cap sheet over tapered and flat insulation on the existing steel and tectum decks. REI also designed new structural steel dunnage with a catwalk for the new rooftop mechanical units, and reinforcement of the existing roof structure to carry them. The roofing details tie the new roof into the school's existing metal roof sections, which were not disturbed. REI assisted with bidding and is administering construction.


Scope of Work

  • Investigated the flat roofs by visual and infrared survey, and observed investigative test cuts

  • Designed a 4-ply asphalt fiberglass built-up roof with reflective mineral-surfaced cap sheet (hybrid system) over tapered and flat insulation on steel and tectum roof decks

  • Designed new structural steel dunnage with a catwalk for new rooftop mechanical units, and reinforcement of the existing roof structure

  • Prepared roof plans locating new mechanical equipment and existing and new penetrations, and structural plans of existing and new work

  • Detailed expansion joint replacement, perimeter and through-wall flashings, tie-ins to the existing metal roofs, and flashings at dunnage penetrations, equipment curbs and drains

  • Assisted with bidding; providing construction administration, including submittal review, site visits and progress meetings


Project Details

Client: RTM Engineering Consultants, for St. Mary's County Public Schools

Location: Lexington Park, Maryland

Market: K-12 Education

Project Category: Roofing

REI Role: Subconsultant to RTM Engineering Consultants, LLC (formerly Alban Engineering)

Status: Ongoing (construction administration underway)

Area / Quantity: Approximately 57,700 square feet of flat roofing

System(s): 4-ply asphalt fiberglass built-up roof with reflective mineral-surfaced cap sheet (hybrid system) over tapered and flat insulation; structural steel dunnage with catwalk

Related REI Work: Green Holly ES sloped (metal) roof replacement, 2021

Services: Roof Condition Assessment • Infrared Roof Survey • Roof Replacement Design • Structural Dunnage Design • Bidding Assistance • Submittal Review • Construction Administration

bottom of page