top of page

›

George Mason Elementary School Roof Maintenance Coating

Field investigation and design for a silicone maintenance coating over the aged CSPE (Hypalon) roofs of a 40,000 square foot school roof, with bidding assistance and construction administration through a 10-year manufacturer's coating warranty.

George Mason Elementary School Roof Maintenance Coating

Overview

For Alexandria City Public Schools, REI investigated the 40,000 square foot roof at George Mason Elementary School and designed a silicone maintenance coating over the existing CSPE ("Hypalon") single-ply roof sections to extend their useful service life without a full replacement. To suit the scope, REI prepared streamlined design documents: specifications with an abbreviated scope of work and a single drawing sheet with a roof plan of every roof section and its existing system, isometric coating details for typical laps, edges, walls and penetrations, and coating details drawn over photographs of actual conditions on the roof. REI assisted with bidding and provided construction administration, including submittal and change order reviews, field observations and a punch list inspection. During construction, an infrared moisture survey found wet insulation along one wall, which REI traced to an inadequate base flashing termination; REI recommended adding through-wall flashing there, and roof vents were installed where significant moisture was found. The work was substantially complete in January 2021.


Scope of Work

  • Performed a field investigation of the 40,000 square foot roof and mapped each roof section and its existing roofing system

  • Designed cleaning, repair and silicone coating of the aged CSPE membranes and flashings, including replacement drain clamping rings and domes

  • Prepared specifications and a drawing sheet with a roof plan, isometric coating details and photo-based details of actual roof conditions

  • Assisted with bidding and recommended the contract award

  • Reviewed submittals and a change order for 115 lineal feet of new through-wall flashing where an infrared survey found wet insulation

  • Observed construction and performed the punch list inspection


Results

  • Extended the service life of the existing roofs with a coating instead of a full replacement

  • About 35,600 square feet of roof coated, covered by a 10-year manufacturer's coating warranty (2021-2031) and a 2-year installer's warranty

  • Corrected a leak source at the base of a masonry wall with new through-wall flashing during the project

  • Substantially complete in January 2021; REI's punch list inspection rated the quality of the installation excellent, with a limited number of items


Project Details

Client: Alexandria City Public Schools

Location: Alexandria, Virginia

Market: K-12 Education

Project Category: Roofing

REI Role: Prime Consultant

Design Completed: July 2020

Construction Substantially Completed: January 2021

Area / Quantity: 40,000 SF roof; about 35,600 SF (356 squares) coated

System(s): Soprema Alsan SIL 402 silicone roof coating (25 mil dry film) over existing CSPE (Hypalon) single-ply membrane and flashings; Replacement drain clamping rings and domes; roof vents to release trapped moisture where the infrared survey found wet insulation; 115 LF of new through-wall flashing at one masonry wall

Contractor: CHU Contracting, Inc.

Warranty: 10-year manufacturer's coating warranty; 2-year installer's warranty

Location: 2601 Cameron Mills Road, Alexandria, Virginia

Services: Roof Condition Assessment • Roof Maintenance and Repair • Bidding Assistance • Submittal Review • Construction Administration

bottom of page