Washington Dulles International Airport C/D Terminal Roof Investigation and Replacement
Infrared survey, condition investigation and replacement design for approximately 400,000 square feet of single-ply roofing on the C/D Terminal at Washington Dulles International Airport.

Overview
As a subconsultant to Gensler, REI performed a comprehensive investigation of the roofing systems on the C/D Terminal Building at Washington Dulles International Airport for the Metropolitan Washington Airports Authority, to determine the remaining life of the roofs and the maintenance and repairs needed to extend it. The investigation included infrared thermography of the entire roof and investigative test cuts. REI's report concluded that complete replacement was the most prudent solution in both cost and effectiveness. REI then prepared drawings and specifications to replace the existing CSPE (Hypalon) roofing with mechanically fastened TPO roofing, and provided contract administration during construction under the airport's security protocols.
Scope of Work
Performed infrared thermography of the entire roof to locate moisture within the roof system
Made investigative test cuts to identify existing substrates, and prepared a report of observations and findings
Designed replacement of approximately 400,000 square feet of CSPE (Hypalon) single-ply roofing with mechanically fastened 60-mil TPO over tapered and flat polyisocyanurate insulation on steel roof decks
Detailed expansion joint replacement, conduit penetrations, gravel stops, modifications to metal wall panels and flashings throughout the roof
Prepared technical specifications, including a Rhinobond fastening system
Provided contract administration, including submittal review and site visits under airport security protocols
Results
Showed that complete replacement was the most prudent solution, in both cost and effectiveness, compared with continued maintenance and repair
Project Details
Client: Metropolitan Washington Airports Authority (through Gensler)
Location: Dulles, Virginia
Market: Aviation
Project Category: Roofing
REI Role: Subconsultant to Gensler
Year: 2016
Area / Quantity: Approximately 400,000 SF
System(s): Mechanically fastened 60-mil TPO (Rhinobond fastening) over tapered and flat polyisocyanurate insulation on steel roof decks; replaced CSPE (Hypalon) single-ply roofing
Services: Roof Condition Assessment • Infrared Roof Survey • Roof Replacement Design • Submittal Review • Construction Administration