Bladensburg Branch Library Rainscreen Wall Peer Review
Building envelope peer review, during construction, of the rainscreen wall design for a new branch library in Prince George's County, covering the zinc and metal rainscreen cladding, its attachment system, continuous insulation and air/vapor barrier, with recommended detail and specification changes.

Overview
During construction of the new Bladensburg Branch Library at 4820 Annapolis Road, the general contractor, Scheibel Construction, engaged REI to peer review the rainscreen wall system shown in the project documents. The building's walls combine horizontal zinc standing seam siding and metal siding panels with zinc diamond and flat lap shingles, mounted on a pre-engineered rainscreen attachment system over 2 inches of continuous rigid insulation, an air and vapor barrier membrane and exterior sheathing on 8-inch steel studs. REI reviewed the architectural bid drawings and the building envelope specification sections, together with the Requests for Information, Architect's Directives, change proposals and air barrier submittal issued as the wall questions were worked out in the field. REI marked up the drawings, sketched alternate details, and issued its comments in February 2022 as a combined review letter and as separate letters with the recommendations directed to the Architect and to the Contractor.
Scope of Work
Reviewed the architectural bid drawings, including the wall sections and roof, parapet, scupper, awning and penthouse details, for the two rainscreen wall assemblies
Reviewed the specification sections for sheathing, insulation, air and vapor barrier, metal and composite wall panels, the rainscreen attachment system, flashing and sheet metal, and joint sealants
Reviewed the RFIs, Architect's Directives and related change proposals on rainscreen depth, attachment, cavity insulation, metal decking and the angled fin walls
Reviewed the air and vapor barrier submittal and manufacturer guidance on sealing fastener penetrations
Marked up the drawings and Directive sketches with comments and sketched REI alternate details for the rainscreen tie-in at the roof edge and the offset wall at the top of the masonry veneer
Results
Recommended an air and vapor barrier that is self-sealing at fastener penetrations, since the cladding must be fastened through the membrane, and a manufacturer review of the intended application
Recommended a plywood substrate fastened to the horizontal girts, with the air and vapor barrier installed over it, in place of fastening blind through the insulation to the studs, to reduce missed fasteners and membrane penetrations
Identified details needed for fastening, terminations, openings, and transitions to the masonry veneer, curtainwall and roofing, and called for engineered, sealed shop drawings of the attachment
Recommended specification clarifications for wind design to ASCE 7, sheathing type, flashing cleats and underlayment, and sealants
Project Details
Client: Scheibel Construction
Location: Bladensburg, Maryland
Market: Government
Project Category: Peer Review
REI Role: Building Envelope Peer Reviewer to Scheibel Construction (general contractor)
Documents Reviewed: Bid drawings dated September 2020; RFIs, Architect's Directives and change proposals from July 2021 - February 2022
Review Issued: February 2022
Systems Reviewed: Zinc standing seam siding, metal siding panels and zinc diamond and flat lap shingles on a pre-engineered rainscreen attachment system; 2-inch continuous rigid insulation, air and vapor barrier membrane and exterior sheathing on 8-inch steel studs; Transitions to masonry veneer, curtainwall and TPO roofing
Owner: Prince George's County
Design Stage Reviewed: Bid drawings and specifications, with RFIs, Architect's Directives and change proposals issued during construction
Services: Design Peer Review • Specification Review • Constructability Review • Submittal Review