Atlantic United Methodist Church Roof Replacement
Roof survey, replacement design and construction administration for an Ocean City church campus, converting shingle roofs to standing seam metal and replacing low-slope roofs with PVC over tapered insulation.

Overview
REI was retained by Atlantic United Methodist Church to survey every roof on its Ocean City, Maryland campus, which includes a 1960s sanctuary framed with glued-laminated wood arches, a steeple, a social hall and a 1997 addition. REI's November 2024 report set out conditions, remaining service life and cost estimates for each roof section. REI then designed the roof replacement, evaluated bids and administered construction through closeout in 2026.
Scope of Work
Surveyed all roof sections, including test cuts, and reported conditions, remaining service life and estimated costs
Prepared construction documents and specifications for 0.032-inch prefinished aluminum standing seam roofing over new insulation at steep-slope areas
Specified 60-mil PVC roofing over flat and tapered polyiso insulation at low-slope areas, with new aluminum gutters and downspouts
Designed new steel dunnage for the relocated cooling tower, and specified repointing of the steeple, mechanical room and chimney masonry
Evaluated five contractor bids, including alternates and unit prices, for the Board of Trustees
Provided construction administration: submittal reviews, observation reports, payment reviews, punch list and closeout
Results
Replaced the sanctuary's shingle roof, over wood plank decking that was essentially uninsulated, with standing seam metal roofing over new continuous insulation
Corrected long-standing ponding on the low-slope roof, visible in decades of satellite imagery, with tapered insulation
Unit-price repair quantities were reconciled at closeout, reducing the final contract amount
Project Details
Client: Atlantic United Methodist Church
Location: Ocean City, Maryland
Market: Religious
Project Category: Roofing
REI Role: Prime Consultant
Design Completed: April 2025
Construction Completed: March 2026
System(s): 0.032-inch prefinished aluminum standing seam metal roofing; 60-mil PVC over tapered polyiso insulation
Other Work: Steel cooling tower dunnage; repointing at the steeple, mechanical room and chimney
Services: Roof Condition Assessment • Roof Replacement Design • Structural Dunnage Design • Masonry Restoration Design • Bidding Assistance • Construction Administration