top of page

›

4747 Bethesda Avenue Roof and Penthouse Terrace Ballast Design

Wind uplift analysis and ballast zoning for the protected membrane roof, green roof and penthouse terraces of a 15-story office building in Bethesda, Maryland.

4747 Bethesda Avenue Roof and Penthouse Terrace Ballast Design

Overview

4747 Bethesda Avenue is a 15-story office building in downtown Bethesda, Maryland. Its main roof and penthouse level are finished with a protected membrane roof system covered by pavers, stone, wood decking and green roof areas. At more than 150 feet, the roofs are above the height covered by the SPRI RP-4 ballast tables, so the ballast had to be designed with ASCE 7 calculations. REI analyzed the wind pressures at the main roof and penthouse, accounting for the parapet heights. REI then marked up the landscape materials plans to show ballast zones around the perimeters and corners. The zones combined strapped concrete pavers, heavier perimeter stone, and growth media with erosion control netting, with lighter ballast in the field.


Scope of Work

  • Reviewed the roof and penthouse landscape materials plans and roof details

  • Analyzed wind pressures at the main roof and penthouse under ASCE 7, accounting for building height and parapet height

  • Defined perimeter, corner and field ballast zones for pavers, stone, decking and green roof areas

  • Marked up the roof and penthouse materials plans with ballast requirements, including strapped pavers and erosion control netting


Project Details

Client: 4747 Bethesda Avenue

Location: Bethesda, Maryland

Market: Commercial

Project Category: Roofing

REI Role: Wind Uplift and Ballast Design Engineer

Analysis: 2019

Building: 15-story office building

System(s): Protected membrane roof with concrete pavers, stone ballast, wood decking and vegetative roof areas

Services: Wind Uplift Analysis • Roof Ballast Design